Perle Systems Network Router S 10G STS User Manual

Perle 10G  
Media Converters  
Installation Guide  
S-10G-STS  
S-10G-XTS  
S-10G-XTX  
S-10G-XTSH  
S-10G-XTXH  
P/N 5500325-10  
 
Front and Rear Panel Components  
Front View  
Rear View  
Perle S- 10G Media Converter Installation Guide  
3
 
Installation  
The default switch setting (all switches in the UP position) will work  
for most installations. These are the steps required to configure  
the Perle S-10G standalone media converter:  
1. Set the DIP switch settings.(optional)  
2. Connect the grounding lug. (optional)  
3. Connect the power cord strain relief clip. (optional)  
4. Insert the fiber or copper modules.  
5. Connect the fiber or copper cables.  
6. Using the Perle supplied power adapter, plug the power cord  
into the power cord connector at the rear of the chassis.  
7. Plug the other end of the power adapter into an appropriate  
power outlet.  
Note: The S-10G Chassis should always be grounded for safe and  
proper operation. See Grounding the S10-G Chassis  
S-10G-STS  
P/N 5500325-10  
 
S-10G-XTS, S-10G-XTSH  
S-10G-XTX, S-10G-XTXH  
DIP Switch Settings  
The DIP switches are accessible through the opening in the side  
of the enclosure. The function of the DIP switches varies by  
model, so please refer to the appropriate model.  
Note: Switch changes made when the product is powered up take  
effect immediately and will result in a link reset on both ports.  
Perle S- 10G Media Converter Installation Guide  
5
 
Operating Mode (Switch 1)  
Switch Position Mode  
Up (default)  
Down  
Data  
Test  
Data: In Data mode, data will flow between the two fiber  
connections.  
Test: Test Mode is used to run diagnostics, enable loopback and  
for running the Built In Link Tests.  
Note: The Operation Mode (Switch 1) affects the function of DIP  
Switches 2 and 3.  
Link Mode (Switch 2 – Data Mode)  
Switch Position Mode  
Up (default)  
Down  
Smart Link Pass-Through Mode  
Standard Mode  
Smart Link Pass-Through: In this mode, the link state on one  
fiber connection is directly reflected through the media converter to  
the other fiber connection. If fiber link is lost on one of the  
connections, then the other fiber link will be brought down by the  
media converter.  
Standard Mode: In this mode, the links can be brought up and  
down independently of each other. A loss of link on either fiber  
connection can occur without affecting the other fiber connection  
Perle S- 10G Media Converter Installation Guide  
6
 
Test Function (Switch 2 – Test Mode)  
Switch Position Type  
Up (default)  
Down  
Built In Link Test  
Loopback  
Built In Link Test: Switch 2 causes the S-10G to initiate the Built  
In Link Tests on the specified port. Switch 3 determines the  
specified port for the Built In Link Tests. If Switch 3 is Up, the tests  
will be run on Port 1. If the Switch is Down the tests will be run on  
Port 2. The other port will be disabled during these tests.  
These tests consist of the media converter module generating test  
patterns to be sent out the selected port to the remote media  
converter. If the remote media converter is an S-10G, it will  
automatically be put into loopback mode.  
Loopback: If Switch 2 is down, the specified port will be put into  
loopback mode. In this mode the port will be ready to receive the  
test patterns generated by the S-10G running the Built in Link  
Test. Switch 3 determines which port will be put into loopback  
mode. The other port will be disabled during the tests. If the  
remote device is also an S-10G media converter, this unit does not  
need to be put into test mode and there is no need to set the  
loopback switch. This will be taken care of by the Auto Loopback  
feature.  
Illustration of the Built In Link Test / Loopback  
Local S-10G Configuration  
Test Mode (Switch 1 – Down)  
Test Fuction (Switch 2 –Up)  
Remote-S-10G Configuration  
All switches in the Up position  
Perle S- 10G Media Converter Installation Guide  
7
 
Note: If the remote media converter is not a Perle S-10G then the remote  
media converter will need to be put into loopback mode. See the  
documentation that came with that media converter.  
Sequence of Events  
1. The Local S-10G sends the Remote S-10G a signal to go into  
loopback mode.  
2. The Remote S-10G media converter turns on loopback mode.  
3. Built In Test data is sent from the Local S-10G media  
converter to the Remote S-10G media converter.  
4. The Remote S-10G media converter loops the received data  
back to the Local S-10G media converter.  
5. Any test errors detected are displayed with the LEDs on the  
front of the Local S-10G media converter.  
6. The Built in Link Tests continue to run until Switch 1 on the  
Local S-10G media converter is set to Data mode.  
Port Selection (Switch 3 – Test Mode)  
Switch Position Port  
Up (default)  
Down  
1
2
Fiber Fault Alert (Switch 3 – Data Mode)  
Switch Position Mode  
Up (default)  
Down  
Enabled  
Disabled  
Enabled: If the media converter detects a loss of fiber, the media  
converter will immediately notify the fiber link partner that an error  
condition exists.  
If the remote media converter is set up for Fiber Fault Alert (FFA)  
Enabled and the local media converter is set up with Smart Link  
Pass-Through, a loss of fiber link on either the transmit or receive  
line will be passed through to the other fiber connection.  
Disabled: The media converter will not monitor for fiber fault.  
Perle S- 10G Media Converter Installation Guide  
8
 
Illustration of the FFA feature  
Media Converter A Configuration  
Link Mode–Standard Mode  
Fiber Fault Alert  
Media Converter B Configuration  
Link Mode–Smart Link Pass through Mode  
Fiber Fault Alert  
Sequence of Events  
1. Media Converter  
A
A
loses fiber connection (RX).  
2. Media Converter  
notifies the remote Media Converter that  
there is a fault on the Link.  
3. Media Converter  
4. Media Converter  
B
B
detects loss of fiber link on receiver RX.  
turns off transmitter (TX).  
EDC AutoDetect Mode (Switch 4 and Switch 5)  
SFP+ Models Only  
Switch Position Mode  
Up (default)  
Down  
On  
Off  
On: When AutoDetect Mode is turned On, the S-10G media  
converter will establish the linear or limiting settings based on the  
contents of the EPROM on the module and the module type.  
Off: When AutoDetect Mode is turned OFF, the S-10G media  
converter will select the alternative mode that was established by  
the determination above.  
Perle S- 10G Media Converter Installation Guide  
9
 
Operation  
Powering up the Perle Media Converter  
1. Connect the Perle supplied power adapter to the media  
converter.  
2. Turn on the power at the source.  
3. Check that the PWR LED light is lit.  
Status LED  
The Perle 10G Media converters have three status LEDs located  
on the front panel of the unit.  
PWR - Power/Test  
Green On: Power is on and the unit is in normal operation mode.  
Green blinking slowly: the unit is in test or loopback mode.  
Red blinking slowly while in Test mode: indicates an error  
within the last second.  
Red Solid: During power up - hardware error detected.  
Red Blinking quickly: Error detected. (See LK1 LK2 Error  
Codes).  
Red (Solid or Blinking) – A module has been inserted that is  
requesting more than the specified maximum power for that port.  
Perle S- 10G Media Converter Installation Guide  
10  
 
LK1- Port 1 Activity  
On: Fiber link present.  
Blinking quickly: Fiber link present and receiving data.  
Blinking slowly: The fiber link has been taken down as a result of  
Smart Link Pass-Through.  
Blinking one second on, 3 seconds off: the maximum specified  
operating temperature within the inserted module has been  
exceeded.  
Off: No fiber link present.  
LK2 – Port 2 Activity  
On: Fiber link present.  
Blinking quickly: Fiber link present and receiving data.  
Blinking slowly: The fiber link has been taken down as a result of  
Smart Link Pass-Through.  
Blinking one second on, 3 seconds off: the maximum specified  
operating temperature within the inserted module has been  
exceeded.  
Off: No fiber link present.  
LK1 LK2 Error Codes  
LK1  
LK2  
Meaning  
Off  
Off  
Incompatible SFP+ or XFP or speed mismatch on SFP+  
Off  
On  
Power Budget exceeded – XFP’s requesting more power than  
specified port rating.  
On  
On  
Off  
On  
SFP+ or XFP communication error – S-10G unable to  
communicate with module  
Internal Error  
Grounding the S10-G Chassis  
If your installation requires additional grounding follow this  
procedure.  
Grounding the chassis requires the following items:  
One grounding lug (not provided)  
One 18-12 AWG wire (not provided)  
Perle S- 10G Media Converter Installation Guide  
11  
 
Cross-head screwdriver (not provided)  
Note: For your safety, when installing this equipment, always  
ensure that the chassis ground connection is installed first and  
disconnected last.  
Attaching the Grounding Lug  
1. Attach the grounding lug to one end of an 18-12 AWG wire.  
2. Attach the grounding lug to the chassis and secure with the  
grounding screw(s).  
Attaching the Power Cord Strain Relief Clip  
1. Feed the power cord through the opening in the power cord  
relief clip.  
2. Attach the power cord relief clip to the chassis and secure with  
the provided screw.  
3. Plug the power cord into the AC power connector at the rear  
of the chassis.  
4. Plug the other end of the power cord into an appropriate  
power outlet.  
Perle S- 10G Media Converter Installation Guide  
12  
 
Troubleshooting  
General  
Ensure power is supplied to the media converter – use of  
the Perle supplied power adapter is highly recommended.  
Ensure that the SFP+ or XFP modules are of the same  
speed and are operating properly.  
Ensure both devices on either end of each fiber are  
compatible.  
For fiber connections, ensure the RX and TX have been  
reversed between the two media converters.  
No connectivity  
If unable to get full connectivity with all DIP switches in the UP  
position, this procedure is recommended for troubleshooting.  
1. Built In Link Test: Set Switch 2 to the Up position.  
2. Set Switch 3 to the Up position to test port 1 or Switch 3 to the  
Down position to test Port 2.  
3. Loopback: If the remote media converter is a Perle S-10G,  
then the Local Perle S-10G media converter will signal the  
Remote media converter to go into loopback mode. (If the  
remote media converter is not a Perle S-10G, then the remote  
media converter will need to be put into Loopback Mode (See  
the User’s Guide that came with that media converter).  
4. Test Data will be sent from the local S-10G to the Remote  
media converter.  
5. If the PWR LED on the Local S-10G turns red or blinks red on  
a repeated basis, the fiber connection may require further  
testing.  
6. If the PWR LED on the Local S-10G stays green after several  
seconds of testing, then the link is passing the Built In Link  
Test. Proceed to testing the other link.  
P/N 5500325-10  
 
Module Temperature Protection  
Every S-10G comes equipped with an internal fan to provide  
cooling to the unit. However, if any of the modules are operating  
above their specified maximum operating temperature, the S-10G  
will reduce the power to these modules. The S-10G will continue  
to monitor the operating temperature of the unit until the  
temperature is below the maximum operating temperature and  
then the S-10G will return the modules to normal operating.  
Loopback Auto Detect  
Perle S-10G media converters have the ability to automatically put  
remote Perle S-10G media converters in loopback mode. This  
allows the remote S-10G media converter to be located in distant  
or inaccessible locations. The remote S-10G will remain in  
loopback mode as long as the tests are in progress.  
Note: Depending on the manufacturer some copper cabling may not  
support our Loopback Auto Detect feature, however Loopback Mode can  
always be obtained by setting switch 2 to the down position on your  
Perle Media converter.  
Perle S- 10G Media Converter Installation Guide  
14  
 
Technical Specifications  
The following applies to all Perle Standalone S-10G Media  
converters.  
Power Input/Consumption  
1.0A Max, 600mA at 12VDC  
1.2A Max, 800mA at 12VDC  
1.5A Max, 1.0A at 12VDC  
1.5A Max, 1.0A at 12VDC  
2.0A Max, 1.4A at 12VDC  
9-30VDC  
STS  
XTS  
XTX  
XTSH  
XTXH  
Operating Temperature:  
Storage Temperature:  
Operating Humidity:  
Storage Humidity:  
Operating Altitude:  
Weight:  
0°C -50°C (32°F - 122°F)  
-25°C -70°C (-13°F -158°F)  
5% to 90% non-condensing  
5% to 95% non-condensing  
Up to 3,048 m (10,000 ft)  
0.38 kg (0.3 lbs.)  
SFP+ and XFP Support  
MSA Compliant SFP+  
MSA complaint Class 1,2 and 3 XFP modules for the S-10G-  
XTX and S-10G-XTS  
MSA complaint Class 1,2,3 and 4 XFP modules for the S-  
10G-XTXH and S-10G-XTXSH  
1G copper modules  
1G fiber modules  
SFP+ supports Cx1 (direct attach) interfaces  
XFP supports CX4 modules  
Fiber Cabling Requirements  
MM:  
50/125 microns  
62.5/125 microns  
SM:  
9/125 microns  
Note: Please refer to the product page on the Perle website for  
the most up to date specifications.  
Perle S- 10G Media Converter Installation Guide  
15  
 
Compliance Information  
FCC  
This product has been found to comply with the limits for a Class A digital device,  
pursuant to Part 15 of the FCC rules. These limits are designed to provide  
reasonable protection against harmful interference when the equipment is operated  
in a commercial environment. This equipment generates, uses, and can radiate  
radio frequency energy and, if not installed and used in accordance with the  
instructions in this Guide, may cause harmful interference to radio communications.  
Operation of this equipment in a residential area is likely to cause harmful  
interference, in which case the user will be required to correct the interference at  
his/her own expense.  
EN 55022 Class A  
WARNING This is a Class A product. In a domestic environment this product may  
cause radio interference in which case the user may be required to take adequate  
measures.  
EN 55024 Class A  
Contacting Technical Support  
Contact information for the Perle Technical Assistance Center  
(PTAC) can be found at the link below. A Technical Support Query  
may be made via this web page.  
Warranty / Registration  
Perle’s standard Lifetime Warranty provides customers with return  
to factory repairs for Perle products that fail under the conditions of  
the warranty coverage. Details can be found at:  
Copyright © 2012 Perle Systems Limited  
All rights reserved. No part of this document may be reproduced or used in any form  
without written permission from Perle Systems Limited.  
Perle S- 10G Media Converter Installation Guide  
16  
 

Pelco Security Camera C611M C User Manual
Philips Battery Charger SCM4480 User Manual
Philips DVD Recorder DVDR 75 User Manual
Philips Flat Panel Television BDS4624R 00 User Manual
Pioneer Speaker System S FCR3300 K User Manual
Polar Heart Rate Monitor S210 User Manual
Polaroid Flat Panel Television TLX 02610B User Manual
Poulan Blower BP402 LE User Manual
Poulan Pole Saw 545117550 User Manual
Poulan Tiller 96082000900 User Manual