Pelco Home Security System C2406M F User Manual

INSTALLATION/OPERATION  
200 Series Camclosure®  
Integrated Camera System  
®
C2406M-F (4/04)  
 
DESCRIPTION  
The wedge style 200 Series Camclosure® integrated camera system is designed to mount directly  
to a wall or ceiling. It also can mount to a corner with the ICS200-CM corner mount. The system  
incorporates a camera and lens package into a small, medium security enclosure.  
C2406M-F (4/04)  
3
 
INSTALLATION  
The following parts are supplied:  
1
1
1
3
3
1
Camclosure integrated camera system  
Watertight mounting plate  
1/8-inch pin-in-hex Allen wrench bit  
10-32 x 0.5-inch Phillips screws  
#10 internal tooth lock washers  
Hole plug  
PREPARE MOUNTING SURFACE  
CAMERA  
ASSEMBLY  
PHILLIPS  
SCREW  
1. Remove the cover of the ICS200. Use the  
screwdriver bit that is provided to loosen the three  
tamperproof screws, and then lift the cover from  
the base.  
2. Remove the camera module from the base: remove  
the Phillips screw on each side of the camera  
assembly and unplug the electrical connectors.  
Refer to Figure 1.  
Figure 1. Removing Camera Module  
3. Outdoor Installation – Refer to Figure 2 and select the mounting pattern: fixed or adjustable.  
Use the watertight mounting plate as a template and mark the fastener hole positions on the  
mounting surface. Prepare the holes for the fasteners.  
Indoor Installation – Refer to Figure 2 and select the mounting pattern: fixed or adjustable.  
Use the base of the ICS200 as a template and mark the fastener hole positions on the  
mounting surface. Prepare the holes for the fasteners.  
NOTE: The watertight mounting plate is not required for indoor installations.  
FIXED MOUNTING  
PATTERN  
ADJUSTABLE  
MOUNTING  
PATTERN  
Figure 2. Mounting Patterns (Watertight Mounting Plate Shown)  
4
C2406M-F (4/04)  
 
INSTALL BASE  
WITHOUT CONDUIT  
1. Outdoor Installation Only – Bring the power and video wiring for the camera through the  
wiring hole in the watertight mounting plate. Then fasten the mounting plate to the mounting  
surface with #8 stainless steel screws (not provided) of the appropriate length.  
2. Connect power input wires to the wires in the  
FOUR-PIN  
POWER  
base of the Camclosure.  
CONNECTOR  
24 VAC  
24 VAC – Connect power to the red and blue wires.  
12 VDC  
12 VDC – a. Connect +12 VDC to the red wire and  
ground to the black wire.  
b. Reset the voltage jumper on the  
camera power board. Refer to  
Figure 3. Remove the jumper  
from JP1 (AC) and reinstall the  
jumper on JP2 (DC).  
Figure 3. Voltage Jumper Settings  
3. Connect the video cable. Make sure the boot covers the BNC connectors.  
4. Push the power wires and video cable back through the mounting surface. Line up the  
mounting holes in the base with the mounting holes on the mounting surface, and attach the  
base as follows:  
If you are attaching the base to the watertight mounting plate, use the three 10-32 x 0.625-inch  
screws and lock washers that are provided.  
If you are fastening the base directly to a wall or ceiling, use appropriate hardware (not  
supplied). Use 1/4-20 hex head bolts with wall anchors in high-vandalism installations.  
WITH CONDUIT  
HOLE PLUG  
WATERTIGHT  
MOUNTING PLATE  
1. Outdoor Installation Only –  
Insert the hole plug that is  
supplied into the large hole in the  
water-tight mounting plate (refer  
to Figure 4). Then fasten the  
mounting plate to the mounting  
surface with #10 stainless steel  
screws (not provided) of the  
appropriate length.  
Figure 4. Install Hole Plug  
2. Using a blunt tool push out the wiring plug in the  
C2406M-F (4/04)  
5
 
bottom of the base (refer to Figure 5). Pull the  
wiring inside the base.  
WARNING: Be careful not to damage  
the wiring or the connection where the  
video cable is fastened to the circuit  
board.  
3. Using the screwdriver bit that is provided, remove the  
conduit cover and plate by unscrewing the  
tamperproof screw. Refer to Figure 6.  
4. Install a 3/4-inch (1.91 cm) conduit connector  
in the conduit opening.  
Figure 5. Wiring Plug Removal  
5. Line up the mounting holes in the base with the mounting holes on the mounting surface, and  
attach the base as follows:  
If you are attaching the base to the watertight mounting plate, use the three 10-32 x 0.625-inch  
screws and lock washers that are provided.  
If you are fastening the base directly to a wall or ceiling, use appropriate hardware (not  
supplied). Use 1/4-20 hex head bolts with wall anchors in high-vandalism installations.  
6. Attach the base to the conduit.  
7. Connect power input wires to the wires in the base of the Camclosure.  
24 VAC – Connect power to the red and blue wires.  
12 VDC – a. Connect +12 VDC to the blue wire and ground to the black wire.  
b. Reset the voltage jumper on the camera power board. Refer to Figure 7. Remove  
the jumper from JP1 (AC) and reinstall the jumper on JP2 (DC).  
8. Connect the video cable. Make sure the boot covers the BNC connectors.  
9. Push the power wires and video cable back through the conduit fitting.  
Figure 6. Base Installation with Conduit  
FOUR-PIN  
POWER  
CONNECTOR  
CONDUIT  
COVER  
24 VAC  
12 VDC  
PLATE  
Figure 7. Voltage Jumper Settings  
6
C2406M-F (4/04)  
 
REINSTALL CAMERA MODULE  
1. Reinstall the camera module. Refer to Figure 8. Make sure the top of the camera is oriented  
properly. On the lens housing, look for the label that says TOP.  
WARNING: To prevent damage to the camera or lens, the camera must be  
installed in the proper hole of the mounting bracket. If the camera is not installed in  
the correct hole, the window of the enclosure may be forced against the lens.  
MOUNT CAMERAS WITH  
2.9 AND 3.6 MM LENSES  
MOUNT CAMERAS WITH  
6, 8, AND 12 MM AND  
VARIFOCAL LENSES  
Figure 8. Camera Installation  
2. Reconnect the electrical connections. If you do not need the heater, do not plug in the four-pin  
heater connector with red, orange, and black wires.  
ADJUST POSITION  
1. Turn on power to the camera and monitor.  
VARIFOCAL LENS  
CAUTION: Heater elements could be  
hot! When camera power is on, use  
caution when adjusting the camera.  
This applies to all models.  
LOCKING  
SCREWS  
2. Varifocal Lens Only – Loosen the focal length  
and focus locking screws (refer to Figure 9). Adjust  
according to scene detail. Retighten the screws.  
Figure 9. Varifocal Lens Adjustment  
3. Adjust the position of the camera.  
4. Adjustable Mounting Pattern Only – Refer to  
Figure 10. Adjust the angle of the base and tighten  
mounting hardware. If the watertight mounting  
plate is installed, remove the base, adjust the  
mounting plate, and reinstall the base.  
REPLACE COVER  
Figure 10. Adjustable Mounting Pattern  
Place the cover of the ICS200 onto the base of the unit.  
Use the screwdriver bit (provided) and tighten the three  
tamperproof screws.  
C2406M-F (4/04)  
7
 
ADJUSTMENTS (COLOR CAMERA ONLY)  
If you have a color camera, it is set up at the factory and normally requires no adjustments.  
Sometimes, however, adjustments may be necessary.  
1. Remove the cover using the supplied 1/8-inch hollow screwdriver bit.  
2. Adjust the vertical phase, iris level, focus, or switch settings (refer to procedures below).  
3. Replace the cover.  
FIXED LENS  
VERTICAL PHASE  
(24 VAC OPERATION ONLY)  
Adjustment is required if there is vertical roll when  
switching between two cameras.  
VERTICAL  
PHASE  
ADJUSTMENT  
1. Reverse the 24 VAC connections on one camera. If  
both cameras are connected to the same  
transformer, this should solve the problem.  
VARIFOCAL LENS  
2. If reversing the connections does not solve the  
problem, or if cameras are connected to different  
transformers, turn the adjustment screw on one  
camera (while switching as rapidly as possible  
between the two camera views) until the  
switching is clean and there is no vertical roll. If  
more than two cameras are out of synchronization  
with each other, choose one camera and  
VERTICAL PHASE  
ADJUSTMENT  
synchronize all others to it.  
Figure 11. Vertical Phase Adjustment  
AUTO IRIS LEVEL ADJUSTMENT  
If you have a varifocal lens or fixed focal length lens with an auto iris, you can adjust the iris level  
setting to increase or decrease brightness.  
VARIFOCAL LENS  
FIXED LENS  
IRIS LEVEL  
ADJUSTMENT  
AUTO IRIS LEVEL  
ADJUSTMENT  
Figure 12. Iris Level Adjustment  
8
C2406M-F (4/04)  
 
FOCUS ADJUSTMENT FOR FIXED FOCAL LENGTH LENS WITH AUTO IRIS  
C A U T I O N  
Heater elements could be hot! When camera power is on, use caution  
when adjusting the camera.  
To adjust the focus, do the following:  
FOCUS  
1. Loosen the locking screw on the bottom of the  
ADJUSTMENT  
SCREW  
lens. To loosen the screw, it may be necessary to  
remove the heater board. Refer to Figure 14 and  
the accompanying steps.  
2. Move the screw in the slot to bring the picture into  
ADJUSTMENT  
SLOT  
focus.  
BOTTOM VIEW OF CAMERA WITH  
HEATER BOARD REMOVED  
3. Retighten the locking screw.  
Figure 13. Focus Adjustment  
4. Replace the heater board if it was removed.  
5. Reconnect the four-pin heater connector if you are  
using the heater.  
To remove the heater board, do the following:  
HEATER  
BOARD  
1. Disconnect the four-pin heater connector (red,  
orange, and black wires) if it is plugged in.  
2. Wait for the heater elements to cool if they are  
hot.  
3. Apply pressure and press on the corner of the  
board.  
Figure 14. Removing Heater Board  
C2406M-F (4/04)  
9
 
SWITCH SETTINGS FOR FIXED FOCAL LENGTH LENS WITH AUTO IRIS  
Refer to Figure 15. The switch is located next to the lens. Automatic backlight compensation  
(factory setting) is used under varying lighting conditions (such as outdoors) or fixed lighting  
conditions where there are no bright spots that darken other picture details. Manual backlight  
compensation is used in fixed lighting conditions to optimize the picture detail when there are  
bright spots.  
FACTORY SETTINGS  
ALC/ELC switch:  
Always ALC  
Always DC  
Y/DC switch:  
ON  
Auto backlight compensation:  
BLC switch OFF  
ABL switch ON  
OFF  
Manual backlight compensation: BLC switch ON  
ABL switch OFF  
= SWITCH POSITION  
Figure 15. Switch Settings for  
Fixed Lens with  
Auto Iris  
SWITCH SETTINGS FOR FIXED FOCAL LENGTH LENS WITHOUT AUTO IRIS  
Refer to Figure 16. The switch is located next to the lens. Automatic backlight compensation  
(factory setting) is used under varying lighting conditions (such as outdoors) or fixed lighting  
conditions where there are no bright spots that darken other picture details. Manual backlight  
compensation is used in fixed lighting conditions to optimize the picture detail when there are  
bright spots.  
FACTORY SETTINGS  
ALC/ELC switch:  
Always ELC  
Not used  
Y/DC switch:  
ON  
Auto backlight compensation:  
BLC switch OFF  
ABL switch ON  
OFF  
Manual backlight compensation: BLC switch ON  
ABL switch OFF  
= SWITCH POSITION  
Figure 16. Switch Settings for  
Fixed Lens Without  
Auto Iris  
10  
C2406M-F (4/04)  
 
SWITCH SETTINGS FOR VARIFOCAL LENS  
The high resolution camera  
with varifocal lens and  
auto iris is configured at  
the factory for optimal  
performance in lighting  
conditions where auto iris  
is required. It is also  
configured with the shutter  
speed set at 1/60 (NTSC) or  
1/50 (PAL) and AGC set at  
6 dB of gain.  
1
2
3
4
5
6
7
8
AWB Automatic white balance  
GAM Gamma function  
AGC Automatic gain control  
ESC Electronic shutter control  
BLC Backlight compensation  
FACTORY SETTINGS  
1
2
3
4
5
6
7
8
OFF  
FL  
Flickerless  
= SWITCH POSITION  
AE Automatic exposure  
Not used  
Figure 17. Switch Settings for Varifocal Lens  
To enable automatic exposure  
To enable auto iris and manually set  
shutter speed  
Turn off switch 7; set switches 4, 5, and 6 for  
the desired shutter speed.  
Turn on switch 7, and then turn on/off switch 4  
for electronic shutter control, switch 5 for  
backlight compensation, and switch 6 for  
flickerless motion.  
CAUTION Do not change the shutter speed  
unless you understand how changing the  
settings will affect the scene detail.  
To manually set and lock AWB  
Place a white background in front of camera  
and turn off switch 1.  
Switch Number and Position  
Shutter  
Speed  
7
6
5
4
For gamma correction  
1/60 (NTSC)  
1/50 (PAL)  
Switch to accurately reproduce scene  
brightness; when turned on, y = 0.6, and when  
turned off, y = 1.0.  
On  
On  
On  
1/100  
1/250  
1/500  
1/1000  
1/2000  
1/4000  
1/10000  
Off  
On  
Off  
On  
Off  
On  
Off  
On  
Off  
Off  
On  
On  
Off  
Off  
On  
On  
On  
Off  
Off  
Off  
Off  
Off  
For gain control  
Switch 3 On increases gain by 6 dB, and  
switch 3 Off increases gain by 18 dB.  
Figure 18. Varifocal Lens Shutter Speed  
Settings  
C2406M-F (4/04)  
11  
 
SPECIFICATIONS  
General  
Pan/Tilt Adjustment: Manual; ±10° pan; 5° above horizontal to 20° below horizontal tilt; additional  
24° pan adjustment when installing using the adjustable mounting pattern in  
base  
Rating:  
Meets NEMA Type 4 and IP66 standards  
Aluminum base and cover, steel camera mounting bracket  
Gray polyester powder coat  
Construction:  
Finish:  
Dimensions  
Without  
Watertight  
Mounting Plate: 3.29 (H) x 3.26 (W) x 6.20 (L) inches (8.36 x 8.28 x 15.70 cm)  
With Watertight  
Mounting Plate: 3.69 (H) x 3.26 (W) x 6.20 (L) inches (9.37 x 8.28 x 15.70 cm)  
Operating  
Temperature:  
-50° to 122°F (-46° to 50°C)  
De-ices to 25°F (-4°C)  
Heater:  
Turns on at 50°F (10°C) and off at 80°F (27°C)  
Low temperature, indoor/outdoor  
1.25 lb (0.57 kg)  
Environment:  
Unit Weight:  
Electrical  
Input Voltage:  
12 VDC or 24 VAC, ±10%  
Power Consumption: 13 watts or less  
Video Connector: BNC  
(Design and product specifications subject to change without notice.)  
12  
C2406M-F (4/04)  
 
REGULATORY NOTICES  
FCC Class A (monochrome, EIA cameras only)  
This equipment has been tested and found to comply with the limits of a Class A digital device,  
pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection  
against harmful interference when the equipment is operated in a commercial environment. This  
equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in  
accordance with the instruction manual, may cause harmful interference to radio communications.  
Operation of this equipment in a residential area is likely to cause harmful interference in which  
case the user will be required to correct the interference at his own expense.  
FCC Class B (color, NTSC cameras only)  
This equipment has been tested and found to comply with the limits of a Class B digital device,  
pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection  
against harmful interference in a residential installation. This equipment generates, uses, and can  
radiate radio frequency energy and, if not installed and used in accordance with the instructions,  
may cause harmful interference to radio communications. However there is no guarantee that the  
interference will not occur in a particular installation. If this equipment does cause harmful  
interference to radio or television reception, which can be determined by turning the equipment off  
and on, the user is encouraged to try to correct the interference by one or more of the following  
measures:  
Reorient or relocate the receiving antenna.  
Increase the separation between the equipment and the receiver.  
Connect the equipment into an outlet on a circuit different from that to which the receiver is  
connected.  
Consult the dealer or an experienced radio/TV technician for help.  
C2406M-F (4/04)  
 
13  
WARRANTY AND RETURN INFORMATION  
WARRANTY  
Pelco will repair or replace, without charge, any merchandise proved defective in material or workmanship for a period of one year after the date of  
shipment. Exceptions to this warranty are as noted below:  
Five years on Pelco manufactured cameras (CC3500/CC3600/CC3700 and MC3500/MC3600 Series); two years on all other cameras.  
Three years on Genex® Series (multiplexers, server, and keyboard) and 090 Series Camclosure® Camera System.  
Two years on 100/150, 200 and 300 Series Camclosure® Camera Systems.  
Two years on all standard motorized or fixed focal length lenses.  
Two years on Legacy®, CM6700/CM6800/CM8500/CM9500/CM9740/CM9760 Matrix, DF5 and DF8 Series Fixed Dome products.  
Two years on Spectra®, Esprit®, and PS20 Scanners, including when used in continuous motion applications.  
Two years on Esprit and WW5700 series window wiper (excluding wiper blades).  
Eighteen months on DX Series digital video recorders.  
One year (except video heads) on video cassette recorders (VCRs). Video heads will be covered for a period of six months.  
Six months on all pan and tilts, scanners or preset lenses used in continuous motion applications (that is, preset scan, tour and auto scan modes).  
Pelco will warrant all replacement parts and repairs for 90 days from the date of Pelco shipment. All goods requiring warranty repair shall be sent  
freight prepaid to Pelco, Clovis, California. Repairs made necessary by reason of misuse, alteration, normal wear, or accident are not covered under  
this warranty.  
Pelco assumes no risk and shall be subject to no liability for damages or loss resulting from the specific use or application made of the Products.  
Pelco’s liability for any claim, whether based on breach of contract, negligence, infringement of any rights of any party or product liability, relating to  
the Products shall not exceed the price paid by the Dealer to Pelco for such Products. In no event will Pelco be liable for any special, incidental or  
consequential damages (including loss of use, loss of profit and claims of third parties) however caused, whether by the negligence of Pelco or  
otherwise.  
The above warranty provides the Dealer with specific legal rights. The Dealer may also have additional rights, which are subject to variation from  
state to state.  
If a warranty repair is required, the Dealer must contact Pelco at (800) 289-9100 or (559) 292-1981 to obtain a Repair Authorization number (RA), and  
provide the following information:  
1. Model and serial number  
2. Date of shipment, P.O. number, Sales Order number, or Pelco invoice number  
3. Details of the defect or problem  
If there is a dispute regarding the warranty of a product which does not fall under the warranty conditions stated above, please include a written  
explanation with the product when returned.  
Method of return shipment shall be the same or equal to the method by which the item was received by Pelco.  
RETURNS  
In order to expedite parts returned to the factory for repair or credit, please call the factory at (800) 289-9100 or (559) 292-1981 to obtain an  
authorization number (CA number if returned for credit, and RA number if returned for repair).  
All merchandise returned for credit may be subject to a 20% restocking and refurbishing charge.  
Goods returned for repair or credit should be clearly identified with the assigned CA or RA number and freight should be prepaid. Ship to the  
appropriate address below.  
If you are located within the continental U.S., Alaska, Hawaii or Puerto Rico:  
If you are located outside the continental U.S., Alaska, Hawaii or  
Puerto Rico:  
Service Department  
Pelco  
3500 Pelco Way  
Clovis, CA 93612-5699  
Intermediate Consignee  
American Overseas Air Freight  
320 Beach Road  
Ultimate Consignee  
Pelco  
3500 Pelco Way  
Clovis, CA 93612-5699  
USA  
Burlingame, CA 94010  
USA  
® Pelco, the Pelco logo, Spectra, Genex, Legacy, Esprit, and Camclosure are registered trademarks of Pelco.  
© Copyright 2004, Pelco. All rights reserved.  
14  
C2406M-F (4/04)  
 
REVISION HISTORY  
Manual #  
C2406M  
Date  
11/99  
1/00  
2/00  
11/00  
1/01  
Comments  
Original version.  
Revised installation instructions. Added FCC notices.  
Added varifocal lens. Changed format.  
New camera module design, revised installation instructions.  
Revised heater element caution.  
C2406M-A  
C2406M-B  
C2406M-C  
C2406M-D  
1/03  
Revised manual for new mounting bracket for camera. Revised camera drawings to show new  
design.  
C2408M-E  
C2408M-F  
4/03  
4/04  
Added instructions for fixed lens with auto iris.  
Changed format. Revised installation instructions to include watertight mounting plate per  
ECO#03-9060.  
C2406M-F (4/04)  
15  
 
®
World Headquarters  
3500 Pelco Way  
Clovis, California 93612 USA  
USA & Canada  
Tel: 800/289-9100  
Fax: 800/289-9150  
International  
Tel: 1-559/292-1981  
Fax: 1-559/348-1120  
ISO9001  
Orangeburg, New York Las Vegas, Nevada Eindhoven, The Netherlands Wokingham, United Kingdom Montreal, Canada Singapore  
|
|
|
|
|
 

Peavey Music Mixer AMR 64 User Manual
Peavey Music Mixer UMA 12T User Manual
Peavey Stereo Equalizer Q 131 User Manual
Philips All in One Printer DP C262 User Manual
Philips Iron GC4411 User Manual
Philips Lawn Mower QG3280 User Manual
Philips Power Supply LR03PB4C User Manual
Philips TV VCR Combo 21PV708 715 908 918 39 User Manual
Polar Heart Rate Monitor FT7 User Manual
PowerLogix Computer Accessories COM128 User Manual